Gas Detector Tube

Airtight Glove Box (With Internal Pressure Control) With Outlet

Airtight Glove Box (With Internal Pressure Control) With Outlet

AS ONE Corporation

• Size (mm): 535 x 1290 x 500
• Minimum differential pressure/Minimum display unit pressure: 0.01 kPa/0.05 kPa
• Material : Main unit/Transparent PMMA (Acrylic Plastic) , Valve and Vacuum Meter Mounting Unit/Polycarbonate , Hinge Base/PMMA (acrylic)
• External Connections
• *Air supply port (negative pressure side): outer diameter f8 mm tube (one-touch)
• *Gas (You can also use air.) Supply port (positive pressure side): outer diameter f8 mm tube (one-touch)
• *Exhaust port: outer diameter f10 mm tube (one-touch)
• Supply Air Pressure: 0.4 to 0.6 MPa (Consumption: 80 L/min (ANR))
• Supply gas pressure: 0.6 MPa or less
• Power supply: AC100V 50/60 Hz
• Outlet specs: 2 AC100V outlets
• Weight: 53 kg
• Accessory: Valve x 1 piece (outer diameter f14 mm), glove large x 1 pair for glove box
$0
Ozone Sterilization Locker 900 x 450 x 1800 without Shelf Board

Ozone Sterilization Locker 900 x 450 x 1800 without Shelf Board

AS ONE Corporation

• Model number: OSL-H
• Size (mm): 900 x 450 x 1800
• Specification: without shelf board
• Material: Body/Stainless steel (SUS304)
• Ozone generation amount: Approximately 50mg/h (outlet port concentration: 10ppm)
• Timer: 15, 30, 60, 90 minutes
• Power supply: AC100V 50/60Hz
• Power consumption: 6.4W
• Power cord length: 1.8m
• Recommended exchange time of excimer lamp: Approximately 2000 hours
• Powerful emission of strong ozone gas not only eliminates germs and bacteria but also it also has deodorizing effect against mold smells and similar odors.
• No hazardous NOX(nitrogen oxide)is generated because excimer lamp is used to generate ozone gas.
• This cabinet has low-heat generation and is maintenance-free, making it usable for long time.
• After excimer lamp is turned off, ozone gas is automatically forcibly removed from cabinet.
• LED lamp flashes to notify that ozone concentration has decreased to safe level.
$0
Ozone Sterilization Locker 900 x 450 x 1800 with 5 Shelf Boards

Ozone Sterilization Locker 900 x 450 x 1800 with 5 Shelf Boards

AS ONE Corporation

• Model number: OSL-S
• Size (mm): 900 x 450 x 1800
• Specification: with 5 shelf boards
• Material: Body/Stainless steel (SUS304)
• Ozone generation amount: Approximately 50mg/h (outlet port concentration: 10ppm)
• Timer: 15, 30, 60, 90 minutes
• Power supply: AC100V 50/60Hz
• Power consumption: 6.4W
• Power cord length: 1.8m
• Recommended exchange time of excimer lamp: Approximately 2000 hours
• Powerful emission of strong ozone gas not only eliminates germs and bacteria but also it also has deodorizing effect against mold smells and similar odors.
• No hazardous NOX(nitrogen oxide)is generated because excimer lamp is used to generate ozone gas.
• This cabinet has low-heat generation and is maintenance-free, making it usable for long time.
• After excimer lamp is turned off, ozone gas is automatically forcibly removed from cabinet.
• LED lamp flashes to notify that ozone concentration has decreased to safe level.
$0
Economy Tubular Electric Furnace

Economy Tubular Electric Furnace

AS ONE Corporation

• Outer dimensions (mm): 210 x 210 x 290
• Inner dimensions (mm): 50 x 140
• Inner capacity (L): 0.3
• Temperature settings range: 100 to: 900 ?C/Temperature: 800 ?C
• Temperature setting resolution: 1 ?C
• Time setting resolution: 1 minute
• Timer: ON/OFF/SV timer
• Temperature control method: PID control
• Safety mechanism: Sensor abnormality detection, over-rise prevention relay, over-current fuse
• Sensor: K class thermocouple
• Heater capacity: 800W
• Material: Exterior/Steel, Heat resistant coating, Furnace/Ceramic fiber
• Power supply: AC100V 50/60Hz
• Weight: about 5.2kg
• *There is no core tube attached to the main body. Be sure to use the core tube during operation.
• Easy-to-use compact and personal tubular electric furnace
• Compact design: A compact, personal, general-purpose tubular electric furnace.
• Speedy temperature rise: A high-performance type with a rapid temperature rise time of approximately 28 minutes to the maximum temperature.
• Heating under inert environment possible: By using the gas substitution unit, heat can be performed while replacing with inert gas.
• Temperature setting and furnace temperature can be checked by digital display.
• You can choose the material of the core tube according to the application.
$0