Gas Detector Tube
Gas Detector Tube

Gas Detector Tube Benzene
AS ONE Corporation
• Detecting tube name: 121L benzene
• Number of measurements of 1 box: 5
• Expiration date (year): 3
• Measurement gas name: Benzene
• Measurement range: 0.1 - 65ppm
• Standard suction times (n): 5
• Special remarks: Working environment measurement standard
• Number of measurements of 1 box: 5
• Expiration date (year): 3
• Measurement gas name: Benzene
• Measurement range: 0.1 - 65ppm
• Standard suction times (n): 5
• Special remarks: Working environment measurement standard
$0

Gas Detector Tube Hydrogen Sulfide
AS ONE Corporation
• Detecting tube name: 4LL hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Hydrogen sulfide
• Measurement range: 0.25 - 120ppm
• Standard suction times (n): 1
• Special remarks: Oxygen shortage rule
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Hydrogen sulfide
• Measurement range: 0.25 - 120ppm
• Standard suction times (n): 1
• Special remarks: Oxygen shortage rule
$0

Gas Detector Tube Hydrogen Sulfide
AS ONE Corporation
• Detecting tube name: 4L hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Hydrogen sulfide
• Measurement range: 1 - 240ppm
• Standard suction times (n): 1
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Hydrogen sulfide
• Measurement range: 1 - 240ppm
• Standard suction times (n): 1
$0

Gas Detector Tube Hydrogen Sulfide
AS ONE Corporation
• Detecting tube name: 4LT hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
• Measurement gas name: Hydrogen sulfide
• Measurement range: 0.05 - 4.0ppm
• Standard suction times (n): 1
• Special remarks: Work environment measurement standards, for trace quantitative
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
• Measurement gas name: Hydrogen sulfide
• Measurement range: 0.05 - 4.0ppm
• Standard suction times (n): 1
• Special remarks: Work environment measurement standards, for trace quantitative
$0

Gas Detector Tube Hydrogen Sulfide
AS ONE Corporation
• Detecting tube name: 4LK hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Hydrogen sulfide
• Measurement range: 1 - 40ppm
• Standard suction times (n): 1
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Hydrogen sulfide
• Measurement range: 1 - 40ppm
• Standard suction times (n): 1
$0

Gas Detector Tube Steam
AS ONE Corporation
• Detecting tube name: 6 Water vapor
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Steam
• Measurement range: 0.5 - 32mg/L
• Standard suction times (n): 1
• Special remarks: Humidity measurement
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Steam
• Measurement range: 0.5 - 32mg/L
• Standard suction times (n): 1
• Special remarks: Humidity measurement
$0

Gas Detector Tube Hydrogen Fluoride
AS ONE Corporation
• Detecting tube name: 17LL hydrogen fluoride
• Number of measurements of 1 box: 10
• Expiration date (year): 2
• Measurement gas name: Hydrogen fluoride
• Measurement range: 0.05 - 24ppm
• Standard suction times (n): 5
• Special remarks: Working environment measurement standard
• Number of measurements of 1 box: 10
• Expiration date (year): 2
• Measurement gas name: Hydrogen fluoride
• Measurement range: 0.05 - 24ppm
• Standard suction times (n): 5
• Special remarks: Working environment measurement standard
$0

Gas Detector Tube Steam
AS ONE Corporation
• Detecting tube name: 6LLP water vapor
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Steam
• Measurement range: 2 - 10LB/MMCF
• Standard suction times (n): 2
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Steam
• Measurement range: 2 - 10LB/MMCF
• Standard suction times (n): 2
$0

Gas Detector Tube Carbon Monoxide
AS ONE Corporation
• Detecting tube name: 1L Carbon monoxide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Carbon monoxide
• Measurement range: 2.5 - 2000ppm
• Standard suction times (n): 1
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Carbon monoxide
• Measurement range: 2.5 - 2000ppm
• Standard suction times (n): 1
$0

Gas Detector Tube Hydrogen Sulfide
AS ONE Corporation
• Detecting tube name: 4H Hydrogen sulfide
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Hydrogen sulfide
• Measurement range: 10 - 4000ppm
• Standard suction times (n): 1
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Hydrogen sulfide
• Measurement range: 10 - 4000ppm
• Standard suction times (n): 1
$0

Gas Detector Tube Carbon Dioxide
AS ONE Corporation
• Detecting tube name: 126UH Carbon dioxide
• Number of measurements of 1 box: 10
• Measurement gas name: Carbon dioxide (carbon gas)
• Measurement range: 5 - 50%
• Measurement gas name: Carbon dioxide
• Measurement range: 5 - 50%
• Number of measurements of 1 box: 10
• Measurement gas name: Carbon dioxide (carbon gas)
• Measurement range: 5 - 50%
• Measurement gas name: Carbon dioxide
• Measurement range: 5 - 50%
$0

Gas Detector Tube Carbon Dioxide
AS ONE Corporation
• Detecting tube name: 126SH Carbon dioxide
• Number of measurements of 1 box: 10
• Measurement gas name: Carbon dioxide (carbon gas)
• Measurement range: 1 - 20%
• Measurement gas name: Carbon dioxide
• Measurement range: 1 - 20%
• Number of measurements of 1 box: 10
• Measurement gas name: Carbon dioxide (carbon gas)
• Measurement range: 1 - 20%
• Measurement gas name: Carbon dioxide
• Measurement range: 1 - 20%
$0

Gas Detector Tube Mercaptan
AS ONE Corporation
• Detecting tube name: 70 mercaptan
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Isopropyl mercaptan
• Measurement range: 10 - 240ppm
• Standard suction times (n): 1
• Special remarks: Conversion factor used
• Measurement gas name: Ethyl mercaptan
• Measurement range: 0.5 - 120ppm
• Standard suction times (n): 1
• Special remarks: Conversion factor used
• Measurement gas name: Propyl mercaptan
• Measurement range: 22.5 - 540ppm
• Standard suction times (n): 1
• Special remarks: Conversion factor used
• Measurement gas name: Methyl mercaptan
• Measurement range: 0.35 - 84ppm
• Standard suction times (n): 1
• Special remarks: Conversion factor used
• Measurement gas name: Mercaptans
• Measurement range: 0.5 - 120ppm
• Standard suction times (n): 1
• Number of measurements of 1 box: 10
• Expiration date (year): 3
• Measurement gas name: Isopropyl mercaptan
• Measurement range: 10 - 240ppm
• Standard suction times (n): 1
• Special remarks: Conversion factor used
• Measurement gas name: Ethyl mercaptan
• Measurement range: 0.5 - 120ppm
• Standard suction times (n): 1
• Special remarks: Conversion factor used
• Measurement gas name: Propyl mercaptan
• Measurement range: 22.5 - 540ppm
• Standard suction times (n): 1
• Special remarks: Conversion factor used
• Measurement gas name: Methyl mercaptan
• Measurement range: 0.35 - 84ppm
• Standard suction times (n): 1
• Special remarks: Conversion factor used
• Measurement gas name: Mercaptans
• Measurement range: 0.5 - 120ppm
• Standard suction times (n): 1
$0

Gas Detector Tube Acetaldehyde
AS ONE Corporation
• Detecting tube name: 92 Acetaldehyde
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
•
• Measurement gas name: Acetaldehyde
• ?Measurement range: 5 - 750ppm
• ?Standard suction times (n): 2
• ?Measurement time (hr): -
• ?Special remarks: -
•
• Measurement gas name: Diacetyl
• ?Measurement range: 25 - 1500ppm
• ?Standard suction times (n): 3
• ?Measurement time (hr): -
• ?Special remarks: Used conversion scale
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
•
• Measurement gas name: Acetaldehyde
• ?Measurement range: 5 - 750ppm
• ?Standard suction times (n): 2
• ?Measurement time (hr): -
• ?Special remarks: -
•
• Measurement gas name: Diacetyl
• ?Measurement range: 25 - 1500ppm
• ?Standard suction times (n): 3
• ?Measurement time (hr): -
• ?Special remarks: Used conversion scale
$0

Gas Detector Tube Acetaldehyde
AS ONE Corporation
• Detecting tube name: 92M acetaldehyde
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
•
• Measurement gas name: Acetaldehyde
• ?Measurement range: 2.5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
•
• Measurement gas name: Acetaldehyde
• ?Measurement range: 2.5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -
$0

Gas Detector Tube Acetaldehyde
AS ONE Corporation
• Detecting tube name: 92L acetaldehyde
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
•
• Measurement gas name: Acetaldehyde
• ?Measurement range: 1 - 20ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
•
• Measurement gas name: Acetaldehyde
• ?Measurement range: 1 - 20ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -
$0

Gas Detector Tube Acetone
AS ONE Corporation
• Detecting tube name: 151L Acetone
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
•
• Measurement gas name: Acetone
• ?Measurement range: 50 - 12000ppm
• ?Standard suction times (n): 2
• ?Measurement time (hr): -
• ?Special remarks: Working environment measurement standard
•
• Measurement gas name: Propionaldehyde
• ?Measurement range: 24 - 1880ppm
• ?Standard suction times (n): 2
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Methyl ethyl ketone
• ?Measurement range: 21 - 1680ppm
• ?Standard suction times (n): 5
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
• Number of measurements of 1 box: 10
• Expiration date (year): 2 (refrigeration required)
•
• Measurement gas name: Acetone
• ?Measurement range: 50 - 12000ppm
• ?Standard suction times (n): 2
• ?Measurement time (hr): -
• ?Special remarks: Working environment measurement standard
•
• Measurement gas name: Propionaldehyde
• ?Measurement range: 24 - 1880ppm
• ?Standard suction times (n): 2
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Methyl ethyl ketone
• ?Measurement range: 21 - 1680ppm
• ?Standard suction times (n): 5
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
$0

Gas Detector Tube Amines
AS ONE Corporation
• Detecting tube name: 180. Amines
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•
• Measurement gas name: N,N-Diethylethanolamine
• ?Measurement range: 6 - 120ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N,N-Dimethylethylamine
• ?Measurement range: 4 - 80ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N.N-Dimethylethanolamine
• ?Measurement range: 6.5 - 130ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N-Ethylmorpholine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: n- Butylamine
• ?Measurement range: 8 - 160ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N-Methylmorpholine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: tert-Butylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Amines
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -
•
• Measurement gas name: Ammonia
• ?Measurement range: 1.5 - 30ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Isopropylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethanolamine (monoethanolamine)
• ?Measurement range: 7 - 140ppm
• ?Standard suction times (n): 3
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylenediamine
• ?Measurement range: 14 - 280ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Di -n- Butylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diisopropylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diethylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Cyclohexylamine
• ?Measurement range: 7 - 140ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dipropylamine
• ?Measurement range: 4 - 80ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dimethylaminopropylamine
• ?Measurement range: 8 - 160ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dimethylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Tetramethylenediamine
• ?Measurement range: 8.5 - 170ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Triethylamine
• ?Measurement range: 4.5 - 90ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Trimethylamine
• ?Measurement range: 3.5 - 70ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propylamine
• ?Measurement range: 6 - 120ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Hexylamine
• ?Measurement range: 9 - 180ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Methylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Morpholine
• ?Measurement range: 9 - 180ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propylenimine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•
• Measurement gas name: N,N-Diethylethanolamine
• ?Measurement range: 6 - 120ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N,N-Dimethylethylamine
• ?Measurement range: 4 - 80ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N.N-Dimethylethanolamine
• ?Measurement range: 6.5 - 130ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N-Ethylmorpholine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: n- Butylamine
• ?Measurement range: 8 - 160ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N-Methylmorpholine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: tert-Butylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Amines
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -
•
• Measurement gas name: Ammonia
• ?Measurement range: 1.5 - 30ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Isopropylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethanolamine (monoethanolamine)
• ?Measurement range: 7 - 140ppm
• ?Standard suction times (n): 3
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylenediamine
• ?Measurement range: 14 - 280ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Di -n- Butylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diisopropylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diethylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Cyclohexylamine
• ?Measurement range: 7 - 140ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dipropylamine
• ?Measurement range: 4 - 80ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dimethylaminopropylamine
• ?Measurement range: 8 - 160ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dimethylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Tetramethylenediamine
• ?Measurement range: 8.5 - 170ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Triethylamine
• ?Measurement range: 4.5 - 90ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Trimethylamine
• ?Measurement range: 3.5 - 70ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propylamine
• ?Measurement range: 6 - 120ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Hexylamine
• ?Measurement range: 9 - 180ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Methylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Morpholine
• ?Measurement range: 9 - 180ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propylenimine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
$0

Gas Detector Tube Amines
AS ONE Corporation
• Detecting tube name: 180L amines
• Number of measurements of 1 box: 10
• Expiration date (year): 2
•
• Measurement gas name: N,N-Diethylethanolamine
• ?Measurement range: 0.6 - 12ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N,N-Dimethylethylamine
• ?Measurement range: 0.3 - 6ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N.N-Dimethylethanolamine
• ?Measurement range: 0.65 - 13ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N-Ethylmorpholine
• ?Measurement range: 0.3 - 6ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: n- Butylamine
• ?Measurement range: 0.55 - 11ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Amines
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -
•
• Measurement gas name: Isopropylamine
• ?Measurement range: 0.45 - 9ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethanolamine (monoethanolamine)
• ?Measurement range: 1.95 - 39ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylamine
• ?Measurement range: 0.45 - 9ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylenediamine
• ?Measurement range: 0.9 - 18ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Di -n- Butylamine
• ?Measurement range: 0.4 - 8ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diisopropylamine
• ?Measurement range: 0.3 - 6ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diethylamine
• ?Measurement range: 0.45 - 9ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diethylenetriamine
• ?Measurement range: 0.95 - 19ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Cyclohexylamine
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dipropylamine
• ?Measurement range: 0.35 - 7ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dimethylaminopropylamine
• ?Measurement range: 0.6 - 12ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dimethylamine
• ?Measurement range: 0.45 - 9ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Tetramethylenediamine
• ?Measurement range: 0.8 - 16ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Triethylamine
• ?Measurement range: 0.3 - 6ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Trimethylamine
• ?Measurement range: 0.25 - 5ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propylamine
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propylenimine
• ?Measurement range: 0.35 - 7ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Hexamethyleneimine
• ?Measurement range: 1.55 - 31ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Hexylamine
• ?Measurement range: 0.65 - 13ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Pentamethylenediamine
• ?Measurement range: 0.75 - 15ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Methylamine
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Morpholine
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
• Number of measurements of 1 box: 10
• Expiration date (year): 2
•
• Measurement gas name: N,N-Diethylethanolamine
• ?Measurement range: 0.6 - 12ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N,N-Dimethylethylamine
• ?Measurement range: 0.3 - 6ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N.N-Dimethylethanolamine
• ?Measurement range: 0.65 - 13ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: N-Ethylmorpholine
• ?Measurement range: 0.3 - 6ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: n- Butylamine
• ?Measurement range: 0.55 - 11ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Amines
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -
•
• Measurement gas name: Isopropylamine
• ?Measurement range: 0.45 - 9ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethanolamine (monoethanolamine)
• ?Measurement range: 1.95 - 39ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylamine
• ?Measurement range: 0.45 - 9ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylenediamine
• ?Measurement range: 0.9 - 18ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Di -n- Butylamine
• ?Measurement range: 0.4 - 8ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diisopropylamine
• ?Measurement range: 0.3 - 6ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diethylamine
• ?Measurement range: 0.45 - 9ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Diethylenetriamine
• ?Measurement range: 0.95 - 19ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Cyclohexylamine
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dipropylamine
• ?Measurement range: 0.35 - 7ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dimethylaminopropylamine
• ?Measurement range: 0.6 - 12ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Dimethylamine
• ?Measurement range: 0.45 - 9ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Tetramethylenediamine
• ?Measurement range: 0.8 - 16ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Triethylamine
• ?Measurement range: 0.3 - 6ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Trimethylamine
• ?Measurement range: 0.25 - 5ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propylamine
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propylenimine
• ?Measurement range: 0.35 - 7ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Hexamethyleneimine
• ?Measurement range: 1.55 - 31ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Hexylamine
• ?Measurement range: 0.65 - 13ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Pentamethylenediamine
• ?Measurement range: 0.75 - 15ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Methylamine
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Morpholine
• ?Measurement range: 0.5 - 10ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
$0

Detector tube (Gastech) ammonia
AS ONE Corporation
• Gas name: Ammonia
• measurement range (ppm) : 0.05 to 3.52%
• Quantity : 1 box (Iru 10 pieces)
• *Calibration may not be possible depending on the gas Type.
• measurement range (ppm) : 0.05 to 3.52%
• Quantity : 1 box (Iru 10 pieces)
• *Calibration may not be possible depending on the gas Type.
$0