Stainless Steel Product

Dry Heat Sterilization Instrument Left Door (Right handle, Left Pivot Door)

Dry Heat Sterilization Instrument Left Door (Right handle, Left Pivot Door)

AS ONE Corporation

• Left door (Right handle, Left pivot door)
• External dimensions (mm): 550 x 567 x 760
• Inner dimensions (mm): 450 x 447 x 450
• Temperature adjustment range: R.T. + 20 to 250?
• Material : Exterior/Steel (powder coating), Interior/Stainless steel SUS304 (Partly stainless steel SUS443J1)
• Temperature control method: PID control and SSR output
• Safety device: Digital setting type overrise prevention function, overcurrent breaker burnout mechanism (Heater OFF when sensor is disconnected)
• Power supply : AC100V 50/60Hz
• Heater: 1400W
• Weight: about 40kg
• Accessories: shelf board x 2 pieces, shelf board incl. 2 sets
• *This product is not a medical device.
$0
Dry Heat Sterilization Instrument Left Door (Right handle, Left Pivot Door)

Dry Heat Sterilization Instrument Left Door (Right handle, Left Pivot Door)

AS ONE Corporation

• Left door (Right handle, Left pivot door)
• External dimensions (mm): 400 x 447 x 610
• Inner dimensions (mm): 300 x 327 x 300
• Temperature adjustment range: R.T. + 20 to 250?
• Material : Exterior/Steel (powder coating), Interior/Stainless steel SUS304 (Partly stainless steel SUS443J1)
• Temperature control method: PID control and SSR output
• Safety device: Digital setting type overrise prevention function, overcurrent breaker burnout mechanism (Heater OFF when sensor is disconnected)
• Power supply : AC100V 50/60Hz
• Heater: 800W
• Weight: about 25kg
• Accessories: shelf board x 2 pieces, shelf board incl. 2 sets
• *This product is not a medical device.
$0
Dry Heat Sterilization Instrument Left Door (Right handle, Left Pivot Door)

Dry Heat Sterilization Instrument Left Door (Right handle, Left Pivot Door)

AS ONE Corporation

• Left door (Right handle, Left pivot door)
• External dimensions (mm): 700 x 617 x 810
• Inner dimensions (mm): 600 x 497 x 500
• Temperature adjustment range: R.T. + 20 to 250?
• Material : Exterior/Steel (powder coating), Interior/Stainless steel SUS304 (Partly stainless steel SUS443J1)
• Temperature control method: PID control and SSR output
• Safety device: Digital setting type overrise prevention function, overcurrent breaker burnout mechanism (Heater OFF when sensor is disconnected)
• Power supply : AC100V 50/60Hz
• Heater: 1400W
• Weight: about 50kg
• Accessories: shelf board x 2 pieces, shelf board incl. 2 sets
• *This product is not a medical device.
$0
Dry Heat Sterilization Instrument Right Door (Left Handle Right Pivot Door)

Dry Heat Sterilization Instrument Right Door (Left Handle Right Pivot Door)

AS ONE Corporation

• Right door (Left handle, Right pivot door)
• External dimensions (mm): 400 x 447 x 610
• Inner dimensions (mm): 300 x 327 x 300
• Temperature adjustment range: R.T. + 20 to 250?
• Material : Exterior/Steel (powder coating), Interior/Stainless steel SUS304 (Partly stainless steel SUS443J1)
• Temperature control method: PID control and SSR output
• Safety device: Digital setting type overrise prevention function, overcurrent breaker burnout mechanism (Heater OFF when sensor is disconnected)
• Power supply : AC100V 50/60Hz
• Heater: 800W
• Weight: about 25kg
• Accessories: shelf board x 2 pieces, shelf board incl. 2 sets
• *This product is not a medical device.
$0
Dry Heat Sterilization Instrument Right Door (Left Handle Right Pivot Door)

Dry Heat Sterilization Instrument Right Door (Left Handle Right Pivot Door)

AS ONE Corporation

• Right door (Left handle, Right pivot door)
• External dimensions (mm): 550 x 567 x 760
• Inner dimensions (mm): 450 x 447 x 450
• Temperature adjustment range: R.T. + 20 to 250?
• Material : Exterior/Steel (powder coating), Interior/Stainless steel SUS304 (Partly stainless steel SUS443J1)
• Temperature control method: PID control and SSR output
• Safety device: Digital setting type overrise prevention function, overcurrent breaker burnout mechanism (Heater OFF when sensor is disconnected)
• Power supply : AC100V 50/60Hz
• Heater: 1400W
• Weight: about 40kg
• Accessories: shelf board x 2 pieces, shelf board incl. 2 sets
• *This product is not a medical device.
$0
Dry Heat Sterilization Instrument Right Door (Left Handle Right Pivot Door)

Dry Heat Sterilization Instrument Right Door (Left Handle Right Pivot Door)

AS ONE Corporation

• Right door (Left handle, Right pivot door)
• External dimensions (mm): 700 x 617 x 810
• Inner dimensions (mm): 600 x 497 x 500
• Temperature adjustment range: R.T. + 20 to 250?
• Material : Exterior/Steel (powder coating), Interior/Stainless steel SUS304 (Partly stainless steel SUS443J1)
• Temperature control method: PID control and SSR output
• Safety device: Digital setting type overrise prevention function, overcurrent breaker burnout mechanism (Heater OFF when sensor is disconnected)
• Power supply : AC100V 50/60Hz
• Heater: 1400W
• Weight: about 50kg
• Accessories: shelf board x 2 pieces, shelf board incl. 2 sets
• *This product is not a medical device.
$0
Standard Small Type Desiccator 400 x 350 x 436mm

Standard Small Type Desiccator 400 x 350 x 436mm

AS ONE Corporation

• Material: Body, shelf board/stainless steel (SUS304), Window frame/ABS resin, Observation window/glass
• With rubber feet
• Outer dimensions: 400 x 350 x 436mm
• Inner dimension: 381 x 325 x 364mm
• Weight: 8kg
• Accessories: Shelf board x 1, Key x 1 pieces
• *Silica gel plate is not included in the package.
• Model number: SCD-1L
• Stainless steel casing restrains the effect of static electricity.
• Possible to stack ?two SCD-1L units? or ?one SCD-1L unit and one SCD-2H unit?.
• Grounding terminal is provided on back as countermeasure against static.
$0
Standard Small Type Desiccator 400 x 350 x 862mm

Standard Small Type Desiccator 400 x 350 x 862mm

AS ONE Corporation

• Material: Body, shelf board/stainless steel (SUS304), Window frame/ABS resin, Observation window/glass
• With rubber feet
• Outer dimensions: 400 x 350 x 862mm
• Inner dimension: 381 x 325 x 790mm
• Weight: 13kg
• Accessories: Shelf board x 3, Key x 2 pieces
• *Silica gel plate is not included in the package.
• Model number: SCD-2H
• Stainless steel casing restrains the effect of static electricity.
• Possible to stack ?two SCD-1L units? or ?one SCD-1L unit and one SCD-2H unit?.
• Grounding terminal is provided on back as countermeasure against static.