Control Software

Control Software
Mini-Block Bath

Mini-Block Bath

AS ONE Corporation
• Temperature distribution accuracy: +/- 0.5? or less (at 100?)
• Temperature control system: PID control
• Timer time range: 0 - 999 seconds/0 - 999 minutes
• Temperature rise time (40? -> 100?): 15 minutes or less
• Power supply: 100 - 240VAC 50/60Hz (including AC adapter)
• Power consumption: 35W
• Size: 120 x 152 x 112mm
• Weight: 0.85kg
• Body
• Temperature adjustment range (?): Room temperature +5 - 100
• Front lab
• *Block doesn't come with Body.
• Model number: MyBL-10
• Control Panel : English
• Plug: Type A (https://en.wikipedia.org/wiki/Mains_electricity_by_country)
$0
[Global Model] Digital High Accuracy Temperature Controller 0 - 500? 220V?10%

[Global Model] Digital High Accuracy Temperature Controller 0 - 500? 220V?10%

AS ONE Corporation
• Settings range: 0 - 500?
• Sensor type: K class thermocouple
• Temperature control system: PID control (auto-tuning)
• Temperature display precision: SV +/-3% or 3?, whichever is larger
• Temperature setting system: Sheet key touch system
• Output terminal: M4 screw terminal
• Connection capacity: MAX 7A (resistance load)
• Power supply: 220V?10%(2P plug)
• Size: 135 x 150 x 94mm
• Attached sensor: K class thermocouple f3.2 x 200mm (stainless steel sheath (SUS304)) cable length 1.9m
• Country of origin: Japan
• Control Panel : English
• Plug: Type F(https://en.wikipedia.org/wiki/Mains_electricity_by_country)
$0
Thermal Cycler miniPCR

Thermal Cycler miniPCR

AS ONE Corporation
• Size (mm): 127 x 510 x 102
• Weight (g): 450
• Sample format: 8 x 0.2 mLPCR tube (strip support)
• Temperature rate: Temperature rise/max. 3.2 ?/sec; Temperature fall/max. 2.2 ?/sec
• Temperature Control Method: PID Control
• Temperature range: Ambient temperature to 99 ? (previous protocol storage)
• Power supply: AC100 to 240 V 50/60 Hz 70 W
• Supported systems: Windows (R), Mac, Android
• Protocol: Body save 1 (New protocol can be created by personal computer connection.)
$0
[Global Model] Hot Plate (NINOS) 350? 250 x 250mm 220V?10%

[Global Model] Hot Plate (NINOS) 350? 250 x 250mm 220V?10%

AS ONE Corporation
• Highest temperature (?): 350
• Plate size (mm): 250 x 250
• Temperature settings range: Room temperature +10 - 350?
• Temperature settings: Digital input type
• Temperature distribution width: 4? (*temperature distribution width is indoor environment 25? (no wind, no load, using internal sensor), Reference value when setting to 200?. )
• Temperature control system: Microcomputer type PID control system, ON/OFF control system
• Temperature display system: LCD digital display (setting/measurement temperature simultaneous display, heater output bar graph display)
• Internal temperature sensor: K class thermocouple
• Safety device: Self-diagnosis function (Upper or lower limit temperature abnormality detection, heater abnormality detection, sensor abnormality detection), abnormal heating preventive device (thermostat), overcurrent fuse
• Heater capacity: 1000W
• Additional function: Timer function: Setting range/1 minute - 99 hours 59 minutes (1 minute unit), Program function: Number of steps/maximum 8 steps, repeat times/maximum 9999 times, Setting resolution/temperature 0.1?, time 1 minute, Communication function: PC output (RS232C/D-sub9pin 2m), External temperature sensor supported, Upper or lower limit temperature alarm, Alarm signal output, Settings value memory function, Key lock function, Auto-tuning function
• Plate material: Aluminum (ceramic coating)
• Size: 320 x 360 x 101mm
• Power supply: 220V?10%
• Power cord length: Approx 2m
• *Demonstration equipment 1-4601-31, 32, 41, 42 are available.
• Country of origin: Japan
• Control Panel : English
• Plug: Type F(https://en.wikipedia.org/wiki/Mains_electricity_by_country)
$0
[Global Model] Hot Plate (NINOS) 350? 170 x 170mm 220V?10%

[Global Model] Hot Plate (NINOS) 350? 170 x 170mm 220V?10%

AS ONE Corporation
• Highest temperature (?): 350
• Plate size (mm): 170 x 170
• Temperature settings range: Room temperature +10 - 350?
• Temperature settings: Digital input type
• Temperature distribution width: 4? (*temperature distribution width is indoor environment 25? (no wind, no load, using internal sensor), Reference value when setting to 200?. )
• Temperature control system: Microcomputer type PID control system, ON/OFF control system
• Temperature display system: LCD digital display (setting/measurement temperature simultaneous display, heater output bar graph display)
• Internal temperature sensor: K class thermocouple
• Safety device: Self-diagnosis function (Upper or lower limit temperature abnormality detection, heater abnormality detection, sensor abnormality detection), abnormal heating preventive device (thermostat), overcurrent fuse
• Heater capacity: 680W
• Additional function: Timer function: Setting range/1 minute - 99 hours 59 minutes (1 minute unit), Program function: Number of steps/maximum 8 steps, repeat times/maximum 9999 times, Setting resolution/temperature 0.1?, time 1 minute, Communication function: PC output (RS232C/D-sub9pin 2m), External temperature sensor supported, Upper or lower limit temperature alarm, Alarm signal output, Settings value memory function, Key lock function, Auto-tuning function
• Plate material: Aluminum (ceramic coating)
• Size: 240 x 280 x 101mm
• Power supply: 220V?10%
• Power cord length: Approx 2m
• *Demonstration equipment 1-4601-31, 32, 41, 42 are available.
• Country of origin: Japan
• Control Panel : English
• Plug: Type F(https://en.wikipedia.org/wiki/Mains_electricity_by_country)
$0
Data Recorder Software for Electronic Balance

Data Recorder Software for Electronic Balance

AS ONE Corporation

• Model number: B-16
• Software
• Number of channels: Maximum 16
• Display: English
• Medium: USB memory
• Measurement interval: 5 seconds - 59 seconds (per 1 second), 1 minute - 240 minutes (per 1 minute)
• Supported OS: Windows2000 (SP4 only)/XP (SP2 or greater)/Vista (32 bit only)/7 (32 bit only)
• *Please use it together with conversion cable UC-SGT (optional) for a computer that does not have RS232C terminal. *See http://www.omc-ltd.co.jp/download/asone/b-16_top.html for cable correspondence table.
• Collects balance data by up to 16-channels.
• Sends any setting to multiple channels at regular interval and records received measuring data and time.
• Saves transmission setting for each balance.
• Saves data in CSV format and shows data graphically by spreadsheet software.
$0